Technical catalogue AC Drives
36 Pages

Technical catalogue AC Drives

EMOTRON VFX Emotron VFX 2.0 / High dynamics for demanding applications The Emotron VFX 2.0 AC drive optimizes your process and prevents damage and downtime. The combination of direct torque control, accurate speed control, and efficient vector braking makes it the ideal solution for all dynamic and constant torque applications, such as cranes, crushers, mills, mixers, and centrifuges. Main features UL 840 GOST R 1 • Robust and certified IP54 metal construction as standard offers cost-efficient installation close to the application. • All drive sizes are delivered with a built-in Category C3.

Technical catalogue AC Drives - 3

Emotron VFX 2.0 - IP54 version (Model 48-300 and up also available as IP20 ) Typical motor power at mains voltage 400 V and 460 V * Available for a limited time and as long as drive temperature permits. Rated data at 40 °C ambient temperature ** Number in parenthesis, e.g. G(2), indicates number of parallel power modules. Note: calculate available 230 V motor power by multiplying the 400 V power value (kW) from table above with 0.575 or use motor rated current for drive selection. Example: VFX48-046, 22 kWx 0.575 = 12.6 kW at 230 V

Technical catalogue AC Drives - 4

Emotron VFX 2.0 - IP54 version (Model 69-250 and up also available as IP20 ) Typical motor power at mains voltage 525 V * Available for a limited time and as long as drive temperature permits. Rated data at 40 °C ambient temperature. ** Number in parenthesis, e.g. H69 (2), indicates number of parallel power modules.

Technical catalogue AC Drives - 5

Emotron VFX 2.0 - IP54 version (Model 69-250 and up also available as IP20) Typical motor power at mains voltage 575 V and 690 V * Available for a limited time and as long as drive temperature permits. Rated data at 40 °C ambient temperature ** Number in parenthesis, e.g. H69 (2), indicates number of parallel power modules.

Technical catalogue AC Drives - 6

EMOTRON FDU Emotron FDU 2.0 / Secure the flow and save energy The Emotron FDU 2.0 AC drive is specially developed for controlling variable torque loads such as flow and pressure applications. It continuously adapts motor speed to the level required, minimizing energy consumption and wear. A unique monitoring functionality protects your process from damage and unplanned downtime. Typical applications are pumps, fans, compressors, and blowers. Main features UL 840 GOST R 5 • Robust and certified IP54 metal construction as standard offers cost-efficient installation close to the application. •.

Technical catalogue AC Drives - 7

Emotron FDU 2.0 - IP54 version (Model 48-300 and up also available as IP20) Typical motor power at mains voltage 400 V and 460 V * Available for a limited time and as long as drive temperature permits. Rated data at 40 °C ambient temperature. ** Number in parenthesis, e.g. 1-169(2), indicates number of parallel power modules. Note: calculate available 230 V motor power by multiplying the 400 V power value (kW) from table above with 0.575 or use motor rated current for drive selection. Example: FDU48-046, 22 kWx 0.575 = 12.6 kW at 230 V

Technical catalogue AC Drives - 8

Emotron FDU 2.0 - IP54 version (Model 69-250 and up also available as IP20) Typical motor power at mains voltage 525 V * Available for a limited time and as long as drive temperature permits. Rated data at 40 °C ambient temperature. ** Number in parenthesis, e.g. 1-169(2), indicates number of parallel power modules.

Technical catalogue AC Drives - 9

Emotron FDU 2.0 - IP54 version (Model 69-250 and up also available as IP20) Typical motor power at mains voltage 575 V and 690 V * Available for a limited time and as long as drive temperature permits. Rated data at 40 °C ambient temperature. ** Number in parenthesis, e.g. H69 (2), indicates number of parallel power modules.

Technical catalogue AC Drives - 10

The Emotron VFX/FDU drives are versions, in four different frame All having the same well proven features as the rest of the Emotron Main features mechanical design with easy • Built in DC-choke for reduced • Integrated EMC filter Category • Speed controlled fans for extended equipment lifetime • Built in brake chopper option Typical motor power at mains voltage 400 V and 460 V * Available for a limited time and as long as drive temperature permits. Rated data at 40 °C ambient temperature.

Technical catalogue AC Drives - 11

Technical catalogue AC Drives - 12

General specifications for Emotron VFX/FDU 2.0 Mains voltage: Mains frequency Input total power factor Output voltage Output frequency Output switching frequency Efficiency at nominal load O-Mains supply voltage: * Available for both grounded, corner grounded, and Isolated supply (TN and IT nets). **Nominal voltage selected with parameter. Environmental conditions

Technical catalogue AC Drives - 13

Operation at higher temperatures Most Emotron AC drives are designed for operation at maximum of 40 °C ambient temperature. However, for most models, it is possible to use the AC drive at higher temperatures with reduced output rating. Table 1 shows ambient temperatures as well as deratingfor higher temperatures. 7^/1? / Ambient temperature and derating 400—690 V types Dimensions, weights and cooling air flow The tables below give an overview of the dimensions, weights, and the required air flow for cabinet mounting of the Drives with model numbers up to 48-250 are available as wall mounted.

Technical catalogue AC Drives - 14

Mechanical specifications for models VFX/FDU48 and VFX/FDU52 - IP54 version 1) IP20 module for cabinet mounting. Mechanical specifications for models VFX/FDU69 - IP54 version 1) IP20 module for cabinet mounting.

Technical catalogue AC Drives - 15

Control performance for Emotron VFX 2.0 (Speed) Speed control Static accuracy Speed Control dynamic accuracy (linearity): (impact drop): Closed loop = 0.01% of nnom. Open loop = 0.1% of nnom. Closed loop = 0.2%sec (100% load step) Open loop = 0.4%sec (100% load step) Control performance for Emotron VFX 2.0 (Torque) Torque control static accuracy Torque control dynamic accuracy. Closed loop:

Technical catalogue AC Drives - 16

See "User interface data" on page 20 for connection data and default settings.